Oxygen Sensors

At Process Analyser Systems UK we offer a range of specialised oxygen sensors tailored for diverse gas analysis applications. These sensors support trace and percent O₂ measurements in CO₂-rich environments, inert gases, and hydrocarbon streams. Models such as the A-2C, A-5, B-1, and Instatrace series deliver precise O₂ monitoring, including in acid gas backgrounds, with options for fast response and long life. PAS UK sensors are ideal for applications requiring reliable, accurate O₂ analysis in complex gas mixtures.

triangle_down

Available Oxygen Sensors

A-2C

Part Number: C06689-A2C

Application: Used for trace O2 measurements in CO2 containing backgrounds (0.1-100% CO2) CO2 must be present

Notes: Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.

A-2CXL

Part Number: B74033-A2CXL

Application: Specifically qualified A2C sensor to operate in XL model analyzers. Low range limit is 0-1 ppm

Notes: Use where acid gases are present (CO2, HCl, HCN, etc). CO2 must be present.

A-5

Part Number: C06689-A5

Application:Intermittent or continuous monitoring of percent O2 in gas mixtures containing 0-100% CO2. 90% response time in 45 seconds

Notes: Has more tolerance to exposure to air than A-3. No restrictions on CO2 concentration.

B-1

Part Number: C06689-B1

Application: General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds)

Notes: Use B-3 or C-3 where longer life is required and response time is relatively unimportant. May be used to spot check flue gas.

B-1C

Part Number: C06689-B1C

Application: General purpose percent oxygen analysis where fast response is desired (90% in less than 7 seconds)

B-2C

Part Number: C06689-B2C

Application: General purpose trace O2 analysis for use in inert gas and hydrocarbon streams. Low range limit is 0-10 ppm

Notes: May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.

B-2CXL

Part Number: C06689-B2CXL

Application: Specifically qualified B-2C sensor to operate in XL model analysers. Low range limit is 0-1 ppm

Notes: May be used in CO2 free gas streams containing highly mobile gases such as H2, He and ethylene.

B-3

Part Number: C06689-B3

Application: Percent O2 analysis, best compromise between long life and fast response

Notes: May be used to spot check flue gas.

E-2

Part Number: C57283-E2

Application: Long life cell for use in model 3290 (for use in unattended air liquefaction nitrogen skids)

Notes: Has a 3 to 4 years expected life in air. Minimum range 0-1000 ppm.

Instatrace

Part Number: B71875

Application: Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes

Notes: Used for trace O2 analysis in inert gas and hydrocarbon streams.

Instatrace CO2

Part Number: B73016

Application: Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes

Instatrace XL

Part Number: B73592

Application: Special patented construction provides rapid recovery, during initial cell installation, to low ppm levels by reducing the recovery period from several hours to just minutes

L-2C

Part Number: C06689-L2C

Application: Used for general purpose trace O2 analysis in the 3000T analyser series